CU / MGT / LSZH Fire Resistant Power Cables (FR-H) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, LSZH compound insulated cable.
Insulation Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH Fire Resistant Power Cables (FR-XH) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulated, LSZH compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH / AWA / LSZH Fire Resistant Power Cables (FR-XAH) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulated, LSZH compound, Aluminium wires armoured, LSZH compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / PVC-FR Fire Resistant Power Cables (FR-P) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, PVC-FR compound insulated cable.
Insulation Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC-FR Fire Resistant Power Cables (FR-XP) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulated, PVC-FR compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC / AWA / PVC-FR Fire Resistant Power Cables (FR-XAP) IEC 60502-1, BS 7846

Application : This cable is used in fire extinguishing systems, sprinklers control panels, and exit lights in high-rise buildings, hotel, hospitals sub-ways, and public facilities.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulated, PVC compound, Aluminium wires armoured, PVC-FR compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C, W, Z), SS 299 (C, W, Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH Fire Resistant Power Cables (FR-XH) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH / SWA / LSZH Fire Resistant Power Cables (FR-XSH) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, LSZH Compound, Galvanized steel wires armoured, LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z), IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC-FR Fire Resistant Power Cables (FR-XP) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, PVC-FR compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z), IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC / SWA / PVC-FR Fire Resistant Power Cables (FR-XSP) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, PVC Compound, Galvanized steel wires armoured, PVC-FR compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z), IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH Fire Resistant Power Cables (FR-XH) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, LSZH compound sheathed cable.
Insulation Colour :
4-Core : Red, Yellow, Blue & Black or (Brown Black, Grey & Blue)
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / LSZH / SWA / LSZH Fire Resistant Power Cables (FR-XSH) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, LSZH Compound, Galvanized steel wires armoured, LSZH compound sheathed cable.
Insulation Colour :
4-Core : Red, Yellow, Blue & Black or (Brown Black, Grey & Blue)
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC-FR Fire Resistant Power Cables (FR-XP) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, PVC-FR compound sheathed cable.
Insulation Colour :
4-Core : Red, Yellow, Blue & Black or (Brown Black, Grey & Blue)
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / PVC / SWA / PVC-FR Fire Resistant Power Cables (FR-XSP) IEC 60502-1, BS 7846

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE compound insulated, PVC Compound, Galvanized steel wires armoured, PVC-FR compound sheathed cable.
Insulation Colour :
4-Core : Red, Yellow, Blue & Black or (Brown Black, Grey & Blue)
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings
Sheath Colour : Orange or as per order
Referance Standard : IEC 60502-1 / BS 7846
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLEVA / OSCR / LSZH Fire Resistant Power Cables (FRA-XOL) BS 7629-1

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLEVA compound insulated, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
4-Core : Red, Yellow, Blue & Black or (Brown, Black, Grey & Blue)
Sheath Colour : Orange or as per order
Referance Standard : BS 7629-1
Test Standard : BS EN 50200:2006 PH30, BS EN 50200:2006 Annex E 30min, BS 5839-1:2002+, A2:2008 Clause 26.2d, BS 6387 Cat C.W.Z.

 

CU / MGT / XLEVA / OSCR / LSZH Fire Resistant Power Cables {FRA-XOL(E)} BS 7629-1

Application : This cable is designed for areas where the integrity of the electrical circuit is critical in maintaining power supply. Applications can be found in emergency lightings, control and power circuits, power stations, fire alarm systems, underground tunnels, communications systems, sewage treatment plants, lifts, escalators, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLEVA compound insulated, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
4-Core : Red, Yellow, Blue & Black or (Brown, Black, Grey & Blue)
Sheath Colour : Orange or as per order
Referance Standard : BS 7629-1
Test Standard : BS EN 50200:2006 PH30, BS EN 50200:2006 Annex E 30min, BS 5839-1:2002+, A2:2008 Clause 26.2d, BS 6387 Cat C.W.Z.

 

CU / MGT / XLPE / OSCR / LSZH Fire Resistant Instrumentation Cables (FR-XOL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / LSZH / SWA / LSZH Fire Resistant Instrumentation Cables (FR-XOSL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / PVC-FR Fire Resistant Instrumentation Cables (FR-XOP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC-FR compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / PVC / SWA / PVC-FR Fire Resistant Instrumentation Cables (FR-XOSP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC compound, Galvanized steel wire armoured, PVC-FR compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / LSZH Fire Resistant Instrumentation Cables (FR-XOL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / LSZH / SWA / LSZH Fire Resistant Instrumentation Cables (FR-XOSL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / PVC-FR Fire Resistant Instrumentation Cables (FR-XOP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC-FR compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / OSCR / PVC / SWA / PVC-FR Fire Resistant Instrumentation Cables (FR-XOSP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC compound, Galvanized steel wire armoured, PVC-FR compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / ISOS / LSZH Fire Resistant Instrumentation Cables (FR-XIOL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / ISOS / LSZH / SWA / LSZH Fire Resistant Instrumentation Cables (FR-XIOSL) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / ISOS / PVC-FR Fire Resistant Instrumentation Cables (FR-XIOP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC-FR compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / MGT / XLPE / ISOS / PVC / SWA / PVC-FR Fire Resistant Instrumentation Cables (FR-XIOSP) BS EN 50288-7

Application : This cable is used in machines, measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, mica tape fire barrier, XLPE insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, PVC compound, Galvanized steel wire armoured, PVC-FR compound sheath.
Insulation Colour : White & Black insulation printed with numbers or as per order
Sheath Colour : Orange or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60331, BS 6387 (C,W,Z), SS 299 (C,W,Z) IEC 60332-3, BS 4066-3, BS EN 50266-2-2 IEC 60754-1, BS 6425-1, BS EN 50267-1, IEC 60754-2, BS 6425-2, BS EN 50267-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / LSZH Flame Retardant Power Cables (FRT-H) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, LSZH compound insulated cable.
Insulation Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH Flame Retardant Power Cables (FRT-XH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / AWA / LSZH Flame Retardant Power Cables (FRT-XAH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound, Aluminium wires armoured, LSZH compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH Flame Retardant Power Cables (FRT-XH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
4-Core : Red, Yellow, Blue & Black (Brown, Black, Grey & Blue) or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / SWA / LSZH Flame Retardant Power Cables (FRT-XSH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound, Galvanized steel wires armoured , LSZH compound sheathed cable.
Insulation Colour :
2-Core : Red & Blue or (Brown & Blue)
3-Core : Red, Yellow & Blue or (Brown, Black & Grey)
4-Core : Red, Yellow, Blue & Black (Brown, Black, Grey & Blue) or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH Flame Retardant Power Cables (FRT-XH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound sheathed cable.
Insulation Colour :
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / SWA / LSZH Flame Retardant Power Cables (FRT-XSH) IEC 60502-1, BS 6724

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound, Galvanized steel wires armoured , LSZH compound sheathed cable.
Insulation Colour :
5-Core : Red, Yellow, Blue, Black & Green/Yellow or Brown, Black, Grey, Blue & Green/Yellow
Above 5-Cores : White with Black numberings or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1 / BS 6724
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / OSCR / LSZH Flame Retardant Instrumentation Cables (FRT-XOL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White and Black insulation printed with numbers or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / OSCR / LSZH / SWA / LSZH Flame Retardant Instrumentation Cables (FRT-XOSL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White and Black insulation printed with numbers or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / OSCR / LSZH Flame Retardant Instrumentation Cables (FRT-XOL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / OSCR / LSZH / SWA / LSZH Flame Retardant Instrumentation Cables (FRT-XOSL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White with Black numberings or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / ISOS / LSZH Flame Retardant Instrumentation Cables (FRT-XIOL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound sheath.
Insulation Colour : White and Black insulation printed with numbers or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / ISOS / LSZH / SWA / LSZH Flame Retardant Instrumentation Cables (FRT-XIOSL) BS EN 50288-7

Application : This cable is used in machines measuring instruments, and control systems for the transmission of analogue and digit signals.
Voltage Rating : 500 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulation, Individual laminated aluminium polyster tape with a tinned copper drain wire, Overall laminated aluminium polyster tape with a tinned copper drain wire, LSZH compound, Galvanized steel wire armoured, LSZH compound sheath.
Insulation Colour : White and Black insulation printed with numbers or as per order
Sheath Colour : Black or as per order
Referance Standard : BS EN 50288-7
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / SCT / LSZH / AWA / LSZH Flame Retardant Screened Cables (FRT-XCAH) IEC 60502-1

Application : This cable is mainly used in power stations, mass transit underground passenger systems, airports, petro chemical plants, hotels, hospitals, and high-rise buildings.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE compound insulated, LSZH compound, Screen Copper Tape, LSZH compound, Aluminium wires armoured, LSZH compound sheathed cable.
Insulation Colour : Natural or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / SCT / LSZH / SWA / LSZH Flame Retardant Screened Cables (FRT-XCSH) IEC 60502-1

Application : This cable is primarily used for main power supply. It can be installed in cable ducts, in cable trunking, on cable trays, and on cable ladders.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE Insulated, LSZH compound, Screen Copper Tape, LSZH, Galvanized steel wires armoured, LSZH sheathed cable.
Insulation Colour :
4-Core : (Red, Yellow, Blue & Green/Yellow) (Brown, Black, Grey & Green/Yellow) or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2

 

CU / XLPE / LSZH / LSZH Flame Retardant Screened Cables (FRT-XCH) IEC 60502-1

Application : This cable is primarily used for main power supply. It can be installed in cable ducts, in cable trunking, on cable trays, and on cable ladders.
Voltage Rating : 600/1000 V
Construction : Stranded plain annealed copper conductor, XLPE Insulated, LSZH compound, Screen Copper Tape, LSZH sheathed cable.
Insulation Colour :
4-Core : (Red, Yellow, Blue & Green/Yellow) (Brown, Black, Grey & Green/Yellow) or as per order
Sheath Colour : Black or as per order
Referance Standard : IEC 60502-1
Test Standard : IEC 60332-3, BS 4066-3, BS EN 50266-2-2, IEC 60754-1, BS 6425-1, BS EN 50267-2-1, IEC 60754-2, BS 6425-2, BS EN 50267-2-2, IEC 61034-2, BS 7622-2, BS EN 61034-2